  data sheet june 14, 2010 jrw017/040/060/065/070 series power modules;dc - dc converter 36 - 75vdc input, 1.2vdc to 12vdc output;17a/40a/60a/65a/70a * ul is a registered trademark of underwriters laboratories, inc. ? csa is a registered trademark of canadian standards association. ? vde is a trademark of verband deutscher elektrotechniker e.v. ** iso is a registered trademark of the international organization of standards document no: ds03 - 120 ve r 1.2 5 pdf name: jrw017a0b .pdf features ? compliant to rohs eu directive 2002/95/ec ( - z versions) ? compliant to rohs eu directive 2002/95/ec with lead solder exemption (non - z versions) ? delivers up to 70a output current ? high efficiency ? 91% at 3.3v full load ? improved thermal performa nce: 42a at 70oc at 1m/s (200lfm) for 3.3v o ? low output voltage - supports migration to future ic supply voltages down to 1.0v ? industry standard half brick footprint 61.0 mm x 58.4 mm x 9.5 mm (2. 4 0 in x 2.3 0 in x 0. 3 8 in) ? high p ower density and low output ripple and noise ? 2:1 input voltage range ? constant switching frequency ? output overcurrent/voltage /overtemperature protection ? single tightly regulated output ? remote sense ? adjustable output voltage (+10% / - 20% ) ? negative logic, rem ote on/off ? wide operating temperature range ( - 40c to 85c) ? meets the voltage insulation requirements for etsi 300- 132 - 2 and complies with and is licensed for basic insulation rating per en 60950 ? ce mark meets 73/23/eec and 93/68/eec directives ? ul * 60950 - 1recognized, csa ? c22.2 no. 60950 - 1 - 03 certified, and vde ? 0805:2001 - 12 (en60950- 1) licensed ? iso** 9001 certified manufacturing facilities applications ? distributed power architectures ? wireless networks ? optical and access network equipment ? enterprise netwo rks ? latest generation i c? s (dsp, fpga, asic) and microprocessor powered applications options ? auto restart after fault protection shutdown ? positive logic, remote on/off ? case ground pin ( - h baseplate option) ? active load sharing (parallel operation) d escription the jrw series provide up to 70a output current in an industry standard half brick, which makes it an ideal choice for optimum space, high current and low voltage applications. the converter incorporates synchronous rectification technology and innovative packaging techniques to achieve high efficiency reaching 91% at 3.3v full load. the ultra high efficiency of this converter leads to lower power dissipation such that for most applications a heat sink is not required. the output is fully isolate d from the input, allowing versatile polarity configurations and grounding connections. built - in filtering for both input and output minimizes the need for external filtering. rohs complian t
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 2 a bsolute maximum ratings stresses in excess of the absolute maximum ratings ca n cause permanent damage to the device. these are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. exposure to absolute m aximum ratings for extended periods can adversely affect the device reliability. parameter device symbol min max unit input voltage continuous all v in - 0.3 80 vdc transient (100 ms) v in, trans - 0.3 100 vdc operating ambient temperature all t a - 4 0 85 c (see thermal considerations section) storage temperature all t stg - 55 125 c i/o isolation all 1500 vdc electrical specifications unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and tem perature conditions. parameter device symbol min typ max unit operating input voltage all v in 36 48 75 vdc maximum input current (v in =0 to 75v , i o =i o, max ) all i in,max 7 adc inrush transient all i 2 t 1 a 2 s input reflected ripple curren t, peak - to - peak (5hz to 20mhz, 12h source impedance; v in =0v to 75v, i o = i omax ; see figure 31) all - 15 - map - p input ripple rejection (120hz) all 60 db caution: this power module is not internally fused. an input line fuse must always be used. this power module ca n be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architecture. to preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. the safety agencies require a time - delay fuse with a maximum rating of 20a (see safety considerations section). based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. refer to the fuse manufacturer?s data sheet for further information.
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 3 electrical specifications (continued) parameter device symbol min typ max unit output voltage set - point p v o, set 1.18 1.20 1.22 v dc (v in =v in,nom , i o =i o, max , t ref =25c) m 1.47 1.50 1.52 vdc y 1.77 1.80 1.83 vdc g 2.47 2.50 2.53 vdc f 3.24 3.30 3.36 vdc a 4.95 5.0 5.05 vdc b 11.76 12.0 12.24 vdc output voltage p v o 1.16 ? 1.24 vdc (over all operating input voltag e, resistive load, and temperature m 1.45 ? 1.55 vdc conditions until end of life) y 1.75 ? 1.85 vdc g 2.42 ? 2.58 vdc f 3.20 ? 3.40 vdc a 4.85 ? 5.15 vdc b 11.64 ? 12.36 vdc output regulation line (v in = v in, min to v in, max ) ? 0.05 0.2 % v o, nom load (i o = i o, min to i o, max ) ? 0.05 0.2 % v o, nom temperature (t a = - 40oc to +85oc ) ? 15 50 mv output ripple and noise on nominal output (v in =v in, nom and i o = i o, min to i o, max , c out = 1  f ceramic // 10  f tantalum capacitor) rms (5hz to 20mhz bandwidth) ? ? 40 mv rms peak - to - peak (5hz to 20mhz bandwidth) ? ? 100 mv pk -pk external capacitance p,m,y,g,f c out,ext ? ? 30,000 ) a,b c out,ext ? ? 10,000 ) output current p,m i o 0 ? 70 a g,y 0 ? 65 a f 0 ? 60 a a 0 ? 40 a b 0 ? 17 a output current limit inception p,m i o, cli ? 80 ? a g,y ? 73 ? a f ? 64 ? a a ? 50 ? a b ? 21 ? a output short - circuit current all ? latched - off v o ?p9# o c
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 4 electrical specifications (continued) parameter device symbol min typ max unit efficiency p  84  % (v in =v in,nom , i o =i o, max , v o = v o,set t a =25c) m  86  % y  87  % g  90  % f  91  % a  92  % b  92  % switching freque ncy f sw  300  khz dynamic load response ( ' io/ ' t=1a/10 p s; v in =v in ,nom; t a =25c; tested with a 10 f aluminum and a 1.0 f tantalum capacitor across the load.) load change from io= 50% to 75% of io,max: peak deviation p,m,y,g v pk  6  %v o, set settling time (vo<10% peak deviation) t s  300  p s f,a v pk  4  %v o, set t s  300  p s b v pk  3  %v o, set t s  500  p s load change from io= 75% to 50% of io,max: peak deviation p,m,y,g v pk  6  %v o, set settling time (vo<10% peak deviation) t s  300  p s f,a v pk  4  %v o, set t s  300  p s b v pk  3  %v o, set t s  500  p s isolation specifications parameter symbol min typ max unit isolation capacitance c iso  2700  pf isolation resistance r i so 10   m general specifications parameter min typ max unit calculated mtbf (i o = 80% of i o, max , t a =40c, airflow=1m/s (400lfm) 1,363,000 hours weight  60.3 (2.1)  g (oz.)
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 5 feature specifications unless otherwise indicated, specifications appl y over all operating input voltage, resistive load, and temperature conditions. see feature descriptions for additional information. parameter device symbol min typ max unit remote on/off signal interface (v i = v i ,min to v i , max; open collector or equivalent compatible, signal referenced to v i ( - ) terminal) negative logic: device code suffix ?1? logic low=module on, logic high=module off positive logic: no device code suffix required logic low=module off, logic hig h=module on logic low specification remote on/off current - logic low all i on/off D 0.15 1.0 ma on/off voltage: logic low all v on/off 0.0 D 1.2 v logic high (typ=open collector) all v on/off D D 15 v logic high max imum allowable leakage current all i on/off D D 50 p a turn - on delay and rise times (i o =i o, max ) t delay = time until v o = 10% of v o,set from either p t delay D 2 D msec application of vin with remote on/off set to on or m D 2 D msec operati on of remote on/off from off to on with vin y D 2 D msec already applied for at least one second. g D 5 D msec f D 2 D msec a D 2.5 D msec b D 2.5 D msec t rise = time for v o to rise from 10% of v o,set to 90% of v o,set . p t rise D 1 D msec m D 1 D msec y D 1 D msec g D 3 D msec f D 1 D msec a D 1 D msec b D 1 D msec output voltage adjustment range (trim) output voltage remote sense range v sense D D 10 % v o, nom output voltage set - point adjustment rang e 80 D 110 % v o, nom output over voltage protection p v oovsd 1.4 D 1.6 vdc m 1.8 D 2.2 vdc y 2.3 D 2.6 vdc g 2.9 D 3.4 vdc f 3.8 D 4.6 vdc a 5.7 D 6.5 vdc b 14 D 16 vdc over temperature protection all t ref  127  c input undervo ltage lockout v in, ovlo turn - on threshold  34.5 36 v turn - off threshold 30 32.5  v
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 6 characteristic curves the following figures provide typical characteristics for the jrw017a0b1 (12v, 17a) at 25oc. the figures are ident ical for either positive or negative remote on/off logic. input current,(a) 0 1 2 3 4 5 6 7 25 35 45 55 65 75 i o = 0 a i o = 8.5 a i o = 17 a on/off voltage o utput voltage v on/off (v) (5v/div) v o (v) (5v/div) input voltage, v in (v) time, t (1 ms/div) figure 1. typical start - up (input current) characteristics at room temperature. figure 4. typical start - up characteristics from remote on/off. efficiency (%) 70 75 80 85 90 95 0 3 6 9 12 15 18 v i = 36 v v i = 48 v v i = 75 v output current output voltage i o, (a) (4a/div) v o (v) (200mv/div) output current, i o (a) time, t (100 s/div) figure 2. converter efficiency vs load at room temperature. figure 5. transient response to dynamic load change from 50% to 25% of full load current. output vo ltage v o (v) (20mv/div) output current output voltage i o, (a) (4a/div) v o (v) (200mv/div) time, t (1 s/div) time, t (100 s/div) figure 3. typi cal output ripple and noise at room temperature and i o = i o,max . figure 6. transient response to dynamic load change from 50% to 75 % of full load current. 75 vin 48 vin 36 vin
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 7 characteristic curves (continued) the following figures provide typical characteristics for the jrw 040a0a (5v, 40a) at 25oc. the figures are identical for either positive or negative remote on/off logic. input current,(a) 0 1 2 3 4 5 6 7 25 35 45 55 65 75 i o = 0 a i o = 20 a i o = 40 a on/off voltage o utput voltage v on/off (v) (5v/div) v o (v) (2v/div) input voltage, v in (v) time, t (1 ms/div) figure 7. typical start - up (input current) characteristics at room temperature. figure 10. typical start - up characteristics from remote on/off. efficiency (%) 70 75 80 85 90 95 0 10 20 30 40 v i = 36 v v i = 48 v v i = 75 v output current output voltage i o, (a) (10a/div) v o (v) (200mv/div) output current, i o (a) time, t (100 s/div) figure 8. converter efficiency vs load at room temperature. figure 11. transient response to dynamic load change from 50% to 25% of full load current. output voltage v o (v) (50mv/div) output current output voltage i o, (a) (10a/div) v o (v) (200mv/div) time, t (1 s/div) time, t (100 s/div) figure 9. typical output ripple and noise at room temperature and i o = i o,max . figure 12. transient response to dynamic load change from 25% to 50 % of full load current. 75 vin 48 vin 36 vin
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 8 characteristic curves (continued) the following figures provide typical characteristics for the jrw060a0f (3.3v, 60a)at 25oc. the figures are identical for either positive or negative remote on/off logic. input current,(a) 0 1 2 3 4 5 6 7 8 25 35 45 55 65 75 i o = 0 a i o = 30 a i o = 60 a on/off voltage o utput voltage v on/off (v) (5v/div) v o (v) (1v/div) input voltage, v in (v) time, t (0.5ms/div) figure 13. typical start - up (input current) characteristics at room temperature. figure 16. typical start - up characteristics from remote on/off. efficiency (%) 70 75 80 85 90 95 0 10 20 30 40 50 60 v i = 36 v v i = 48 v v i = 75 v output current output voltage i o, (a) (10a/div) v o (v) (100mv/div) output current, i o (a) time, t (100 s/div) figure 14. converter efficiency vs load at room temperatur e. figure 17. transient response to dynamic load change from 50% to 25% of full load current. output voltage v o (v) (10mv/div) output current output voltage i o, (a) (1 0a/div) v o (v) (100mv/div) time, t (1 s/div) time, t (100 s/div) figure 15. typical output ripple and noise at room temperature and i o = i o,max . figure 18. transient response to dynamic load change from 50% to 75 % of full load cur rent. 75 vin 48 vin 36 vin
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 9 characteristic curves (continued) the following figures provide typical characteristics for the jrw065a0g (2.5v, 65a)at 25oc. the figures are identical for either positive or negative remote on/off logic. input current,(a) 0 1 2 3 4 5 6 25 35 45 55 65 75 i o = 0 a i o = 32.5 a i o = 65 a on/off voltage o u tput voltage v on/off (v) (10v/div) v o (v) (1v/div) input voltage, v in (v) time, t (2ms/div) figure 19. typical start - up (input current) characteristics at room temperature. figure 22. typical start - up characteristics from remote on/off. efficiency (%) 70 75 80 85 90 95 0 10 20 30 40 50 60 70 v i = 36 v v i = 48 v v i = 75 v output current output voltage i o, (a) (10a/div) v o (v) (100mv/div) output current, i o (a) time, t (100 s/div) figu re 20. converter efficiency vs load at room temperature. figure 23. transient response to dynamic load change from 50% to 25% of full load current. output voltage v o (v) (20mv/div) output current output voltag e i o, (a) (10a/div) v o (v) (100mv/div) time, t (2.5 s/div) time, t (100 s/div) figure 21. typical output ripple and noise at room temperature and i o = i o,max . figure 24. transient response to dynamic load change from 25% to 50 % of full load current. 75 vin 48 vin 36 vin
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 10 characteristic curves (continued) the following figures provide typical characteristics for the jrw065a0y (1.8v, 65a) at 25oc. the figures are identical for either positive or negative remote on/off logic. input current,(a) 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 25 35 45 55 65 75 i o = 0 a i o = 32.5 a i o = 65 a on/off voltage o utput voltage v on/off (v) (10v/div) v o (v) (0.5v/div) input voltage, v in (v) time, t (1ms/div) figure 25. typical start - up (in put current) characteristics at room temperature. figure 28. typical start - up characteristics from remote on/off. efficiency (%) 70 72 74 76 78 80 82 84 86 88 90 0 10 20 30 40 50 60 70 v i = 36 v v i = 48 v v i = 75 v output current output voltage i o, (a) (10a/div) v o (v) (100mv/div) output current, i o (a) time, t (200 s/div) figure 26. converter efficiency vs load at room temperature. figure 29. transient response to dynamic load change from 50% to 25% of full load current. output voltage v o (v) (50mv/div) output current output voltage i o, (a) (10a/div) v o (v) (100mv/div) time, t (1 s/div) time, t (200 s/div) figure 27. typical output ripple and noise at room t emperature and i o = i o,max . figure 30. transient response to dynamic load change from 25% to 50 % of full load current. 75 vin 48 vin 36 vin
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 11 characteristic curves (continued) the following figures provide typical characteristics for the jrw070a0m (1.5v, 70a) at 25oc. the figu res are identical for either positive or negative remote on/off logic. input current,(a) 0 0.5 1 1.5 2 2.5 3 3.5 4 25 35 45 55 65 75 i o = 0 a i o = 35 a i o = 70 a on/off voltage o utput voltage v on/off (v) (5v/div) v o (v) (0.5v/div) input voltag e, v in (v) time, t (1ms/div) figure 31. typical start - up (input current) characteristics at room temperature. figure 34. typical start - up characteristics from remote on/off. efficiency (%) 70 72 74 76 78 80 82 84 86 88 90 0 10 20 30 40 50 60 70 v i = 36 v v i = 48 v v i = 75 v output current output voltage i o, (a) (10a/div) v o (v) (100mv/div) output current, i o (a) time, t (200 s/div) figure 32. converter efficiency vs load at room temperature. figure 35. transient response to dynamic load change from 50% to 25% of full load current. output voltage v o (v) (20mv/div) output current output voltage i o, (a) (10a/div) v o (v) (100mv/div) time, t (1 s/div) time, t (2 00 s/div) figure 33. typical output ripple and noise at room temperature and i o = i o,max . figure 36. transient response to dynamic load change from 25% to 50 % of full load current. 75 vin 48 vin 36 vin
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 12 characteristic curves (continued) the following figures provide typical characteristics for the jrw070a0p (1.2v, 70a) at 25oc. the figures are identical for either positive or negative remote on/off logic. input current,(a) 0 0.5 1 1.5 2 2.5 3 3.5 25 35 45 55 65 75 i o = 0 a i o = 35 a i o = 70 a on/off voltage o utput voltage v on/off (v) (5v/div) v o (v) (0.5v/div) input voltage, v in (v) time, t (1ms/div) figure 37. typical start - up (input current) characteristics at room temperature. figure 40. typical start - up characteristics from remote on/off. efficiency (%) 70 72 74 76 78 80 82 84 86 0 10 20 30 40 50 60 70 v i = 36 v v i = 48 v v i = 75 v output current output voltage i o, (a) (10a/div) v o (v) (100mv/div) output current, i o (a) time, t (200 s/div) figure 38. converter efficiency vs load at room temperature. figure 41. tr ansient response to dynamic load change from 50% to 25% of full load current. output voltage v o (v) (20mv/div) output current output voltage i o, (a) (10a/div) v o (v) (100mv/div) time, t (1 s/div) time, t (200 s/div) figure 39. typical output ripple and noise at room temperature and i o = i o,max . figure 42. transient response to dynamic load change from 50% to 75 % of full load current. 75 vin 48 vin 36 vin
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 13 test c onfigurations note: measure input reflected - ripple current with a simulated source inductance ( ltes t) of 12 h. capacitor cs offsets possible battery impedance. measure current as shown above. figure 43. input reflected ripple current test setup. note: use a 1.0 f ceramic capacitor and a 10 f aluminum or tantalum capacitor. scope measurement should be made using a bnc socket. position the load between 51 mm and 76 mm (2 in. and 3 in.) from the module. figure 44. output ripple and noise test setup. n ote: all measurements are taken at the module terminals. when socketing, place kelvin connections at module terminals to avoid measurement errors due to socket contact resistance. figure 45. output voltage and efficiency test setup. design considerat ions input source impedance the power module should be connected to a low ac - impedance source. a highly inductive source impedance can affect the stability of the power module. for the test configuration in figure 43, a 100f electrolytic capacitor (esr< 0 .7 : at 100khz), mounted close to the power module helps ensure the stability of the unit. consult the factory for further application guidelines. output capacitance high output current transient rate of change (high di/dt) loads may require high values of output capacitance to supply the instantaneous energy requirement to the load. to minimize the output voltage transient drop during this transient, low e.s.r. (equivalent series resistance) capacitors may be required, since a high e.s.r. will produce a co rrespondingly higher voltage drop during the current transient. output capacitance and load impedance interact with the power module?s output voltage regulation control system and may produce an ?unstable? output condition for the required values of capac itance and e.s.r.. minimum and maximum values of output capacitance and of the capacitor?s associated e.s.r. may be dictated, depending on the module?s control system. the process of determining the acceptable values of capacitance and e.s.r. is complex a nd is load - dependant. lineage power provides web - based tools to assist the power module end - user in appraising and adjusting the effect of various load conditions and output capacitances on specific power modules for various load conditions. safety conside rations for safety - agency approval of the system in which the power module is used, the power module must be installed in compliance with the spacing and separation requirements of the end - use safety agency standard, i.e ., ul* 60950 - 1 recognized, csa ? c22. 2 no. 60950 -3 - 01 certified, and en 60950- 1 (vde ? 0805): 2001 - 12 licensed. these converters have been evaluated to the spacing requirements for basic insulation per the above safety standards. for basic insulation models (? - b? suffix), 1500 vdc is applied from vi to vo to 100% of outgoing production. for end products connected to ? 48v dc, or ? 60vdc nominal dc mains (i.e. central office dc battery plant), no further fault testing is required.
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 14 safety considerations (continued) *note: - 60v dc nominal batter y plants are not available in the u.s. or canada. for all input voltages, other than dc mains, where the input voltage is less than 60v dc, if the input meets all of the requirements for selv, then: ? the output may be considered selv. output voltages will remain within selv limits even with internally - generated non- selv voltages. single component failure and fault tests were performed in the power converters. ? one pole of the input and one pole of the output are to be grounded, or both circuits are to be kep t floating, to maintain the output voltage to ground voltage within elv or selv limits. for all input sources, other than dc mains, where the input voltage is between 60 and 75v dc (classified as tnv - 2 in europe), the following must be meet, if the conver ter?s output is to be evaluated for selv: ? the input source is to be provided with reinforced insulation from any hazardous voltage, including the ac mains. ? one vi pin and one vo pin are to be reliably earthed, or both the input and output pins are to be kept floating. ? another selv reliability test is conducted on the whole system, as required by the safety agencies, on the combination of supply source and the subject module to verify that under a single fault, hazardous voltages do not appear at the modul e?s output. the power module has elv (extra - low voltage) outputs when all inputs are elv. all flammable materials used in the manufacturing of these modules are rated 94v - 0. the input to these units is to be provided with a maximum 20a fast - acting (or tim e - delay) fuse in the unearthed lead.
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 15 feature description s remote on/off two remote on/off options are available. positive logic remote on/off turns the module on during a logic - high voltage on the on/off pin, and off during a logic low. negative logic remote on/off turns the module off during a logic high and on during a logic low. negative logic, device code suffix "1," is the factory - preferred configuration. to turn the power module on and off, the user must supply a switch to control the voltage between the on/off terminal and the vi ( - ) terminal (von/off). the switch can be an open collector or equivalent (see figure 46). a logic low is von/off = 0 v to i.2 v. the maximum ion/off during a logic low is 1 ma. the switch shoul d maintain a logic - low voltage while sinking 1 ma. during a logic high, the maximum von/off generated by the power module is 15 v. the maximum allowable leakage current of the switch at von/off = 15v is 50 a. if not using the remote on/off feature, perfor m one of the following to turn the unit on: for negative logic, short on/off pin to vi( -). for positive logic: leave on/off pin open. figure 46. remote on/off implementation. overcurrent protection to provide protection in a fault output overload condi tion, the module is equipped with internal current - limiting circuitry and can endure current limit for few seconds. if overcurrent persists for few seconds, the module will shut down and remain latch - off. the overcurrent latch is reset by either cycling th e input power or by toggling the on/off pin for one second. if the output overload condition still exists when the module restarts, it will shut down again. this operation will continue indefinitely until the overcurrent condition is corrected. an auto - res tart option is also available. input undervoltage lockout at input voltages below the input undervoltage lockout limit, the module operation is disabled. the module will begin to operate at an input voltage above the undervoltage lockout turn - on threshold. overtemperature protection these modules feature an overtemperature protection circuit to safeguard against thermal damage. the circuit shuts down and latches off the module when the maximum device reference temperature is exceeded. the module can be res tarted by cycling the dc input power for at least one second or by toggling the remote on/off signal for at least one second. over voltage protection the output overvoltage protection consists of circuitry that monitors the voltage on the output terminals . if the voltage on the output terminals exceeds the over voltage protection threshold, then the module will shutdown and latch off. the overvoltage latch is reset by either cycling the input power for one second or by toggling the on/off signal for one se cond. the protection mechanism is such that the unit can continue in this condition until the fault is cleared. remote sense remote sense minimizes the effects of distribution losses by regulating the voltage at the remote - sense connections. the voltage b etween the remote - sense pins and the output terminals must not exceed the output voltage sense range given in the feature specifications table i.e.: [vo(+) ? vo( - )] ? [sense(+) ? sense( - )] 10% of v o,nom . the voltage between the vo(+) and vo( - ) terminal s must not exceed the minimum output overvoltage shut - down value indicated in the feature specifications table. this limit includes any increase in voltage due to remote - sense compensation and output voltage set - point adjustment (trim). see figure 47. if not using the remote - sense feature to regulate the output at the point of load, then connect sense(+) to vo(+) and sense( - ) to vo(- ) at the module. although the output voltage can be increased by both the remote sense and by the trim, the maximum increase for the output voltage is not the sum of both. the maximum increase is the larger of either the remote sense or the trim. the amount of power delivered by the module is defined as the voltage at the output terminals multiplied by the output current. when u sing remote sense and trim: the output voltage of the module can be increased, which at the same output current would increase the power output of the module. care should be taken to ensure that the maximum output power of the module remains at or below th e maximum rated power.
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 16 feature descriptions (continued) remote sense (continued) figure 47. effective circuit configuration for single - module remote - sense operation output voltage. output voltage programming trimming allows the user to increase or decrease the output voltage set point of a module. this is accomplished by connecting an external resistor between the trim pin and either the sense(+) or sense( - ) pins. the trim resistor should be positioned close to the module. if not using the trim fea ture, leave the trim pin open. with an external resistor between the trim and sense( - ) pins ( radj - down ), the output voltage set point (vo, ad j) decreases (see figure 36). the following equation determines the required external - resistor value to obtain a per centage output voltage change of ? %. for output voltages: 1.2v ? 12v ? ? ? ? ? ? ? ? ? = ? k r down adj 2 % 100 where, 100 % , , ? = ? nom o desired nom o v v v v desired = desired output voltage set point (v). with an external resistor connected between the trim and sense(+) pins ( radj -u p), t he output voltage set point (vo, ad j) increases (see figure 37). the following equation determines the required external - resistor value to obtain a percentage output voltage change of ? %. for output voltages: 1.5v ? 12v ( ) ? ? ? ? ? ? ? ? ? + ? ? ? + = ? k v r nom o up adj % %) * 2 100 ( % * 225 . 1 % 100 * , for output voltage: 1.2v ( ) ? ? ? ? ? ? ? ? ? + ? ? ? + = ? k v r nom o up adj % %) * 2 100 ( % * 6 . 0 % 100 * , where, 100 % , , ? = ? nom o desired nom o v v v v desired = desired output voltage set point (v). the voltage between the vo(+) and vo( - ) terminals must not exceed the minimum output overvoltage shut - down value indicated in the feature specifications table. this limit includes any increase in voltage due to remote - sense compensation and output voltage set - point adjustment (trim). see figure 48. although the output voltage can be increased by both the remote sense and by the trim, the ma ximum increase for the output voltage is not the sum of both. the maximum increase is the larger of either the remote sense or the trim. the amount of power delivered by the module is defined as the voltage at the output terminals multiplied by the output current. when using remote sense and trim, the output voltage of the module can be increased, which at the same output current would increase the power output of the module. care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power. figure 48. circuit configuration to decrease output voltage. figure 49. circuit configuration to increase output voltage.
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 17 feature descriptions (continued) output voltage programming (continued) examples: to trim down the output of a nominal 3.3v module (jrw060a0f) to 3.1v 100 3 . 3 1 . 3 3 . 3 % ? = ? v v v   ? ? ? ? ? ? ? ? = ? k r down adj 2 06 . 6 100 r adj - down = 14.5 k ? to trim up the output of a nominal 3.3v module (jrw060a0f) to 3.6v 100 3 . 3 3 . 3 6 . 3 % ? = ? v v v ?  ( ) ? ? ? ? ? ? ? + ? + = ? k r up adj 1 . 9 ) 1 . 9 * 2 100 ( 1 . 9 * 225 . 1 1 . 9 100 * 3 . 3 r tadj - up = 19.3 k ?
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 18 thermal considerations the power modules operate in a v ariety of thermal environments; however, sufficient cooling should be provided to help ensure reliable operation. considerations include ambient temperature, airflow, module power dissipation, and the need for increased reliability. a reduction in the op erating temperature of the module will result in an increase in reliability. the thermal data presented here is based on physical measurements taken in a wind tunnel. heat - dissipating components are mounted on the topside of the module. heat is removed b y conduction, convection and radiation to the surrounding environment. proper cooling can be verified by measuring the thermal reference temperature (t ref ). the peak temperature (t ref ) occurs at the position indicated in figures 50 - 52. the temperatur e at any one of these locations should not exceed per below table to ensure reliable operation of the power module. figure 50. t ref temperature measurement location for vo= 12v. please refer to the application note ? thermal characterizati on process for open - frame board - mounted power modules ? for a detailed discussion of thermal aspects including maximum device temperatures. figure 51. t ref temperature measurement location for vo= 5v. figure 52. t ref temp erature measurement location s for vo= 3.3v ? 1.2v. the output power of the module should not exceed the rated power for the module as listed in the ordering information table. although the maximum t ref temperature of the power modules is approximatel y 117 c, you can limit this temperature to a lower value for extremely high reliability. heat transfer via convection increased airflow over the module enhances the heat transfer via convection. following derating figures shows the maximum output current that can be delivered by each module in the respective orientation without exceeding the maximum t ref temperature versus local ambient temperature (t a ) for natural convection through 2m/s (400 ft./min). model device temperature( oc) jrw070a0p (1.2v) t ref3 117 jrw070a0m (1.5v) t ref2 / t ref3 115/118 jrw065a0y (1.8v) t ref3 115 jrw065a0g (2.5v) t ref2 / t ref3 117/118 jrw060a0f (3.3v) t ref1 / t ref2 117/118 jrw040a0a (5v) t ref1 117 jrw017a0b (12v) t ref1 117 t ref1 t ref3 t ref1 t ref2 t ref1
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 19 note that the natural convection condition was me asured at 0.05 m/s to 0.1 m/s (10ft./min. to 20 ft./min.); however, systems in which these power modules may be used typically generate natural convection airflow rates of 0.3 m/s (60 ft./min.) due to other heat dissipating components in the system. the us e of figures 53 - 59 are shown in the following example: example what is the minimum airflow necessary for a jrw060a0f operating at vi = 48 v, an output current of 42a, and a maximum ambient temperature of 70 c in transverse orientation. solution: given: vi = 48v io = 48a t a = 70 c determine airflow (v) (use figure 53): v = 1m/sec. (200ft./min.) output current, i o (a) 0 2 4 6 8 10 12 14 16 18 20 20 30 40 50 60 70 80 90 natural convection 1.0 m/s (200 ft./min) 2.0 m/s (400 ft./min) local ambient temperature, t a ( c) figure 53. output power derating for jrw017a0b (vo = 12v) in transverse orientation with no basepla te; airflow direction from vin(+) to vin ( - ); vin = 48v. output current, i o (a) 0 10 20 30 40 50 60 70 20 30 40 50 60 70 80 90 natural convection 1.0 m/s (200 ft./min) 2.0 m/s (400 ft./min) local ambient temperature, t a ( c) figure 55. output power derating for jrw060a0f (vo = 3.3v) in transverse orientation with no baseplate; airflow direction from vin(+) to vin( - ); vin = 48v. output current , i o (a) 0 10 20 30 40 50 60 70 20 30 40 50 60 70 80 90 natural convection 1.0 m/s (200 ft./min) 2.0 m/s (400 ft./min) local ambient temperature, t a ( c) figure 56. output power derating for jrw065a0g (vo = 2.5v) in transverse orientation with no baseplate; airflow direction from vin(+) to vin( - ); vin = 48v. output current, i o (a) 0 10 20 30 40 50 60 70 20 30 40 50 60 70 80 90 natural convection 1.0 m/s (200 ft./min) 2.0 m/s (400 ft./min) local ambient temperatu re, t a ( c) figure 57. output power derating for jrw065a0y (vo = 1.8v) in transverse orientation with no baseplate; airflow direction from vin(+) to vin( - ); vin = 48v. output current, i o (a) 0 5 10 15 20 25 30 35 40 45 50 20 30 40 50 60 70 80 90 natural convection 1.0 m/s (200 ft./min) 2.0 m/s (400 ft./min) local ambient temperature, t a ( c) figure 54. output power derating for jrw040a0a (vo = 5v) in transverse orientation with no baseplate; airflow direction from vin(+) to vin ( - ); vin = 48v.
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 20 output current, i o (a) 0 10 20 30 40 50 60 70 80 20 30 40 50 60 70 80 90 natural convection 1.0 m/s (200 ft./min) 2.0 m/s (400 ft./min) local ambient temperature, t a ( c) figure 58. output po wer derating for jrw070a0m (vo = 1.5v) in transverse orientation with no baseplate; airflow direction from vin(+) to vin( - ); vin = 48v. output current, i o (a) 0 10 20 30 40 50 60 70 80 20 30 40 50 60 70 80 90 natural convection 1.0 m/s (200 ft./min) 2.0 m/s (400 ft./min) local ambient temperature, t a ( c) figure 59. output power derating for jrw070a0p(vo = 1.2v ) in transverse orientation with no baseplate; airflow direction from vin(+) to vin( - ); vin = 48v.
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 21 layout considerations the jrw power module series are low profile in order to be used in f ine pitch system and architectures. as such, component clearances between the bottom of the power module and the mounting board are limited. either avoid placing copper areas on the outer layer directly underneath the power module or maintain a minimum cle arance through air of 0.028 inches between any two ?opposite polarity? components, including copper traces under the module to components on the jrw module.. for modules with a ?7? (case (heatplate) pin) and ? - h? (heatplate) option: to meet basic insulat ion in the end product 1) between the input and output of the module, or 2) between the input and the earth ground, a series capacitor (capable of withstanding 1500v dc) needs to inserted between the case pin and the end termination point, if the case pin is connected to the input or the output of the jrw module or to earth ground. for additional layout guide - lines, refer to fltr100v10 data sheet. post solder cleaning and drying considerations post solder cleaning is usually the final circuit - board assemb ly process prior to electrical board testing. the result of inadequate cleaning and drying can affect both the reliability of a power module and the testability of the finished circuit - board assembly. for guidance on appropriate soldering, cleaning and dry ing procedures, refer to lineage power board mounted power modules: soldering and cleaning application note (ap01 - 056eps). through - hole lead - free soldering information the rohs - compliant through- hole products use the sac (sn/ag/cu) pb - free solder and rohs - compliant components. they are designed to be processed through single or dual wave soldering machines. the pins have an rohs - compliant finish that is compatible with both pb and pb - free wave soldering processes. a maximum preheat rate of 3 c/s is sugge sted. the wave preheat process should be such that the temperature of the power module board is kept below 210 c. for pb solder, the recommended pot temperature is 260 c, while the pb- free solder pot is 270 c max. not all rohs - compliant through - hole pro ducts can be processed with paste - through- hole pb or pb - free reflow process. if additional information is needed, please consult with your lineage power representative for more details.
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 22 mechanical outline dimensions are in millimeters and (inches). tolerances: x.x mm 0.5 mm (x.xx in. 0.02 in.) [unless otherwise indicated] x.xx mm 0.25 mm ( x.xxx in 0.010 in. ) top view side view bottom view topside label includes lineage power name, product designation, and data code. ?option feature, pin is not present unless one these options specified. the i_share and case pin option cannot be specified simultaneously.
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output lineage power 23 recommended pad layout dimensions are in millimeters and (inches). toler ances: x.x mm 0.5 mm (x.xx in. 0.02 in.) [unless otherwise indicated] x.xx mm 0.25 mm ( x.xxx in 0.010 in. )
data sheet june 14, 2010 jrw017 - 070 series power modules dc - dc converters 36- 75vdc input; 1.2vdc to 12vdc output document no: ds03 - 120 ver 1.2 5 p df name: j rw017a0b .pdf ordering information please contact your lineage power sales representative for pricing, availability and o ptional features. table 3. device code product codes input voltage output voltage output current efficiency connector type comcodes jrw017a0b 1 48v (36 - 75vdc) 12v 17a 92% through hole 108967142 jrw040a0a1 48v (36 - 75vdc) 5v 40a 92% through hole 108965385 jrw060a0f1 48v (36 - 75vdc) 3.3v 60a 91% through hole 108965393 jrw065a0g1 48v (36 - 75vdc) 2.5v 65a 90% through hole 108965401 jrw065a0y1 48v (36 - 75vdc) 1.8v 65a 87% through hole 108965435 jrw07 0a0m1 48v (36 - 75vdc) 1.5v 70a 86 % through hole 108965419 JRW070A0P1 48v (36 - 75vdc) 1.2v 70a 84 % through hole 108965427 jrw017a0b1 z 48v (36 - 75vdc) 12v 17a 92% through hole cc109104618 jrw040a0a1 z 48v (36 - 75vdc) 5v 40a 92% through hole cc109107422 jrw0 60a0f1 -hz 48v (36 - 75vdc) 3.3v 60a 91% through hole cc109107455 jrw065a0g1 -hz 48v (36 - 75vdc) 2.5v 65a 90% through hole cc109107471 table 2. device options option device code suffix negative remote on/off logic 1 auto - restart 4 pin length: 3.68 mm 0 .25mm (0.145 in. 0.010 in.) 6 case pin (available with baseplate option only) * 7 basic insulation -b base plate option -h output current share (parallel operation) * -p rohs compliant -z * note: the case pin and ishare pin use the same pin location such that both options cannot be specified simultaneously.


▲Up To Search▲   

 
Price & Availability of JRW070A0P1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X